SFA-82-QCF6SR SFA-82-QCF6SR SKU: SFA-82-QCF6SR
SGFA-47-5I SGFA-47-5I SKU: SGFA-47-5I Description
Method 5I – Determination of Low Level Particulate Matter Emissions – EPA Literature PDF
Method 5I is most effective for PM catches less than 50 mg and is valid for performing correlation of manual PM measurements to PM continuous emission monitors or determining PM emissions from low-level sources such as turbines. After selecting a Method 5 sampling console and an external sample pump in conjunction with a Method 5 kit, simply add a GNFA-47 Method 5I holder to complete the needed parts to perform Method 5I.
The 5I filter holder inlet is constructed of borosilicate glass to hold a 47-mm glass fiber filter with a wafer-thin stainless steel filter support and a Viton® O-ring. The assembly is wrapped with PTFE tape for weighing, averaging less than 35 grams, providing a positive seal against leakage. Method 5I 47-mm filter assembly with glass inlet and stainless steel outlet has two 90 bends.
Designed for paired sampling, our SB-2MD isokinetic sample box accommodates dual probes.
Code: SKU: SGFA-47-5I
Description
Method...
SK-CM23 SK-CM23 SKU: SK-CM23
SK-CM5-V SK-CM5-V SKU: SK-CM5-V
STM-6000 Automated Mercury Sampling Console STM-6000 Automated Mercury Sampling Console SKU: N/A Description
The STM-6000 Automated Mercury Sampling Console captures all data necessary for paired sorbent trap sampling in accordance with PS 12B or Method 30B by simplifying sampling requirements through the automation of data acquisition, sample flow adjustments, leak checks, calculations, temperature control, and calibrations. Data is easily transferred to a Windows-based PC through Ethernet and can be monitored remotely through Modbus connectivity. The meter console controls the sample flow rate proportional to the stack flow rate and determines the standardized volume extracted through each sorbent trap. Designed with easy access to internal components for field service and maintenance.
Features
• User-friendly software and firmware
• Easy data export (text and CSV files)
• Configurable system alarms (dry contact or software)
• Remote input for external test pause and resume
• Packaging options:
▪ Mounts into standard 19” rack
▪ Adaptable environmental enclosures (climate controlled & weatherproof)
• Built for easy maintenance access with drawer slides for convenient serviceability
• Integrated real-time data display and status display
• Configurations available and I/O connections either front or rear
Specifications
Dry Gas Meters:
▪ Model SK25EX series
▪ Positive displacement type
▪ 0.7 liter per revolution
▪ Optical encoder sensor with quadrature pulse output
Sample pumps:
▪ Double-headed
▪ EPDM diaphragms
▪ Maintenance-free brush-less motor
▪ 12 VDC
▪ 220 mbar ultimate vacuum at 1 atmosphere
▪ 10,000 hour MTBF
Sample Flow Control:
▪ Stainless steel sample manifolds fitted with mass flow sensors, vacuum sensors, and proportional valves
▪ Proportional or constant flow sampling
▪ Mass airflow: proportional flow control, 250 to 2000 ccm, port-style, manifold mount
▪ Proportional valve: voltage-sensitive orifice (VSO), 12 VDC
Main Board
▪ RISC-based microcontrollers; main and digital signal processing (DS), a real-time clock with auto backup and write protection to external SRAM
▪ High Speed A/D converter with DSP
▪ SD memory card for data storage – stores up to 99 tests (30-day test runs each), embedded Ethernet Port with full TCP/IP protocol and 256-bit encryption (optional)
▪ USB connection
Sensor Board
▪ Accepts 8 type-K thermocouple inputs
▪ Each channel is fully isolated up to 1.5KV
▪ Integrated barometric pressure sensor
▪ Integrated vacuum sensor
▪ Integrated pressure transducers
Barometric pressure: 600-1100 mbar, 17.7-32.4 inHg, temperature-compensated
Vacuum: 0-30 inHg, 0-101 kPa, 2% accuracy
Integrated Temperature Control: Integrated probe/trap heater control output up 25-amp solid-state relay
Communications:
▪ PC user interface via Ethernet and/or USB
▪ Remote access and control via onboard configurable router to owner’s network computer
▪ Optional TCP/IP MODBUS (ASCII or RTU) communications to the DAS
▪ Optional Interface to DAS system via TCP/IP Modbus
Weight: 34 lbs (15.5 Kg)
Dimensions: (HxWxD) 14” x 17” x 11.25” (35.56 cm x 43.18 cm x 28.58 cm)
Code: SKU: N/A
Description
The STM-6000 Automated Mercury Sampling Console captures all data necessary for paired sorbent trap sampling in accord...
SuperVOST – 0031 Sampling Kit SuperVOST – 0031 Sampling Kit SKU: SuperVOST - 0031 Sampling Kit
Code: SKU: SuperVOST - 0031 Sampling Kit
TEC-1612 Peltier Single-Stage Gas Cooler TEC-1612 Peltier Single-Stage Gas Cooler SKU: TEC-1612 Description
The TEC-1612 has a single easily removable condenser encased in an insulated aluminum block and cooled by two state-of-the-art thermoelectric heat pumps. Dual high-output axial fans are coupled with the latest thermosiphon heat exchangers to support the thermoelectric units and allow the gas conditioner to operate in a wider range of ambient conditions. The condenser is designed to effectively separate condensed moisture from a sample gas, while the integrated peristaltic pump ensures rapid removal of condensation from the system.
The TEC-1612 is the perfect choice for your modular gas sampling system. We listened to feedback and will continue to strive to deliver an effective solution that is lightweight and rugged.
Pinnacle Cooling Technology
Water vapor is removed by cooling the sample gas to a constant dew point with the Apex Pinnacle Heat pump. The Pinnacle assembly in the TEC-1612 utilizes two thermoelectric modules, which operate on the Peltier effect.
Stainless Steel Condenser
The condenser is fabricated from 316 stainless steel and can be treated with a variety of coatings: silicon, polyfluorinated, silane; polar or non-polar. The micro annular flow channel provides maximum condensation efficiency with minimum contact time. The single condenser setup improves response time.
Pinnacle Cooling Unit
The Pinnacle heat pump unit includes a highly conductive aluminum block fitted with two rugged thermoelectric modules, a stainless-steel condenser, a high-efficiency heat exchanger, an exhaust fan, and a PID temperature controller.
The heat pump uses an extremely reliable rugged solid-state thermoelectric module (TEC) and a low-resistance heat exchanger with a copper base and heat pipes with high thermal conductivity for removing heat from the hot side of the TEC and dispersing the heat to the surrounding environment via the exhaust fan.
Specifications:
Pinnacle Heat Pump System: Two 80-watt solid-state modules
Temperature Display: OLED display +/- 0.1 °C/°F
Temperature Control: Variable DC voltage controller, 3-button keypad
Cold Block: Insulated aluminum
Condenser: Alloy 316 stainless steel, reverse flow condensate separator, various coatings available, 1” OD x 12”
Condensate Removal: Integrated peristaltic pump,10 ml/min
Radiator: Two high flow, low-profile heat sinks 120-mm axial fans, with encapsulated motor and electronics
Rated Moisture Extraction Capacity: 14% moisture at 10 lpm (75°ambient) with a less than 1% target moisture rate.
Ambient Operating Temperature: 32 to 104 °F (0 to 40 °C)
Standard Flow Rate: 1 to 15 lpm, single channel
Tubing Size: 1/4“ or 3/8”, accepts 1/4“ line standard
Mounting Options: Standard wall mount
Accessories: Companion condenser, peristaltic pump (optional), separate strain reliefs
Dimensions: 9.5” W x 12” H x 8.8” D (241 mm W x 305 mm H x 224 mm D)
Weight: 26 lbs (11.8 kg)
Code: SKU: TEC-1612
Description
The TEC-1612 has a single easily removable condenser encased in an insulated aluminum block and cooled by two state-...
TEC-1612-S2 TEC-1612-S2 SKU: TEC-1612-S2 Description
The TEC-1612 has a single easily removable condenser encased in an insulated aluminum block and cooled by two state-of-the-art thermoelectric heat pumps. Dual high-output axial fans are coupled with the latest thermosiphon heat exchangers to support the thermoelectric units and allow the gas conditioner to operate in a wider range of ambient conditions. The condenser is designed to effectively separate condensed moisture from a sample gas, while the integrated peristaltic pump ensures rapid removal of condensation from the system.
The TEC-1612 is the perfect choice for your modular gas sampling system. We listened to feedback and will continue to strive to deliver an effective solution that is lightweight and rugged.
Pinnacle Cooling Technology
Water vapor is removed by cooling the sample gas to a constant dew point with the Apex Pinnacle Heat pump. The Pinnacle assembly in the TEC-1612 utilizes two thermoelectric modules, which operate on the Peltier effect.
Stainless Steel Condenser
The condenser is fabricated from 316 stainless steel and can be treated with a variety of coatings: silicon, polyfluorinated, silane; polar or non-polar. The micro annular flow channel provides maximum condensation efficiency with minimum contact time. The single condenser setup improves response time.
Pinnacle Cooling Unit
The Pinnacle heat pump unit includes a highly conductive aluminum block fitted with two rugged thermoelectric modules, a stainless-steel condenser, a high-efficiency heat exchanger, an exhaust fan, and a PID temperature controller.
The heat pump uses an extremely reliable rugged solid-state thermoelectric module (TEC) and a low-resistance heat exchanger with a copper base and heat pipes with high thermal conductivity for removing heat from the hot side of the TEC and dispersing the heat to the surrounding environment via the exhaust fan.
Specifications:
Pinnacle Heat Pump System: Two 80-watt solid-state modules
Temperature Display: OLED display +/- 0.1 °C/°F
Temperature Control: Variable DC voltage controller, 3-button keypad
Cold Block: Insulated aluminum
Condenser: Alloy 316 stainless steel, reverse flow condensate separator, various coatings available, 1” OD x 12”
Condensate Removal: Integrated peristaltic pump,10 ml/min
Radiator: Two high flow, low-profile heat sinks 120-mm axial fans, with encapsulated motor and electronics
Rated Moisture Extraction Capacity: 14% moisture at 10 lpm (75°ambient) with a less than 1% target moisture rate.
Ambient Operating Temperature: 32 to 104 °F (0 to 40 °C)
Standard Flow Rate: 1 to 15 lpm, single channel
Tubing Size: 1/4“ or 3/8”, accepts 1/4“ line standard
Mounting Options: Standard wall mount
Accessories: Companion condenser, peristaltic pump (optional), separate strain reliefs
Dimensions: 9.5” W x 12” H x 8.8” D (241 mm W x 305 mm H x 224 mm D)
Weight: 26 lbs (11.8 kg)
Code: SKU: TEC-1612-S2
Description
The TEC-1612 has a single easily removable condenser encased in an insulated aluminum block and cooled by two state-...
TEC-1612-V TEC-1612-V SKU: TEC-1612-V Description
The TEC-1612 has a single easily removable condenser encased in an insulated aluminum block and cooled by two state-of-the-art thermoelectric heat pumps. Dual high-output axial fans are coupled with the latest thermosiphon heat exchangers to support the thermoelectric units and allow the gas conditioner to operate in a wider range of ambient conditions. The condenser is designed to effectively separate condensed moisture from a sample gas, while the integrated peristaltic pump ensures rapid removal of condensation from the system.
The TEC-1612 is the perfect choice for your modular gas sampling system. We listened to feedback and will continue to strive to deliver an effective solution that is lightweight and rugged.
Pinnacle Cooling Technology
Water vapor is removed by cooling the sample gas to a constant dew point with the Apex Pinnacle Heat pump. The Pinnacle assembly in the TEC-1612 utilizes two thermoelectric modules, which operate on the Peltier effect.
Stainless Steel Condenser
The condenser is fabricated from 316 stainless steel and can be treated with a variety of coatings: silicon, polyfluorinated, silane; polar or non-polar. The micro annular flow channel provides maximum condensation efficiency with minimum contact time. The single condenser setup improves response time.
Pinnacle Cooling Unit
The Pinnacle heat pump unit includes a highly conductive aluminum block fitted with two rugged thermoelectric modules, a stainless-steel condenser, a high-efficiency heat exchanger, an exhaust fan, and a PID temperature controller.
The heat pump uses an extremely reliable rugged solid-state thermoelectric module (TEC) and a low-resistance heat exchanger with a copper base and heat pipes with high thermal conductivity for removing heat from the hot side of the TEC and dispersing the heat to the surrounding environment via the exhaust fan.
Specifications:
Pinnacle Heat Pump System: Two 80-watt solid-state modules
Temperature Display: OLED display +/- 0.1 °C/°F
Temperature Control: Variable DC voltage controller, 3-button keypad
Cold Block: Insulated aluminum
Condenser: Alloy 316 stainless steel, reverse flow condensate separator, various coatings available, 1” OD x 12”
Condensate Removal: Integrated peristaltic pump,10 ml/min
Radiator: Two high flow, low-profile heat sinks 120-mm axial fans, with encapsulated motor and electronics
Rated Moisture Extraction Capacity: 14% moisture at 10 lpm (75°ambient) with a less than 1% target moisture rate.
Ambient Operating Temperature: 32 to 104 °F (0 to 40 °C)
Standard Flow Rate: 1 to 15 lpm, single channel
Tubing Size: 1/4“ or 3/8”, accepts 1/4“ line standard
Mounting Options: Standard wall mount
Accessories: Companion condenser, peristaltic pump (optional), separate strain reliefs
Dimensions: 9.5” W x 12” H x 8.8” D (241 mm W x 305 mm H x 224 mm D)
Weight: 26 lbs (11.8 kg)
Code: SKU: TEC-1612-V
Description
The TEC-1612 has a single easily removable condenser encased in an insulated aluminum block and cooled by two state-...
TEC-1624 Peltier Dual-Stage Gas Cooler TEC-1624 Peltier Dual-Stage Gas Cooler SKU: TEC-1624 Description
The TEC-1624 Thermoelectric Dual-Stage Gas Cooler removes moisture from a gas sample and ensures that the sample is cooled to a constant dew point before reaching the analyzer. The TEC-1624 is designed to be a rack-mountable gas cooler. With its robust two stage single-channel gas conditioning system, the unit efficiently removes condensate and delivers dry gas to the analyzer. The first stage is air-cooled to reduce the dew point of the gas sample and the second stage is actively cooled with thermoelectric modules.
Features
Portable, compact and lightweight
Ideal for high moisture laden gas samples
Rugged solid-state thermoelectric modules
OLED display with power monitor
IP-rated switching power supply
Variable DC voltage PID controller for thermoelectric modules
Peristaltic pump for condensate removal
Standard rack mount
Specifications
Pinnacle Heat Pump System: Two 80-watt solid-state modules
Pre-Cooler: Forced air ambient
Temperature Display: OLED display +/- 0.1 °C/°F Temperature Control: Variable DC voltage controller, 3-button keypad
Cold Block: Insulated aluminum
Condenser: Two Alloy 316 stainless steel, reverse flow condensate separator, various coatings available, 1” OD x 12”
Condensate Removal: Integrated peristaltic pump, 10 ml/min
Radiator: Two sets of dual low-profile heat sinks, 120-mm axial fans, with encapsulated motor and electronics
Rated Moisture Extraction Capacity: 55% moisture at 5 lpm (75° ambient) with a less than 1% target moisture rate.
Ambient Operating Temperature: 32 to 104 °F (0 to 40 °C) Standard Flow Rate: 1 to 15 lpm, single channel Line Size: 1/4“ diameter standard or 3/8” fittings provided
Mounting Options: Rack mount
Accessories: Companion condenser, included peristaltic pump (optional), separate strain reliefs
Dimensions: 19” W x 12” H x 8.8” D (483mm W x 304mm H x 224mm D)
Weight: 39.7 lbs (18.0 kg)
Code: SKU: TEC-1624
Description
The TEC-1624 Thermoelectric Dual-Stage Gas Cooler removes moisture from a gas sample and ensures that the sample is cooled to a const...
TEC-4000Hg TEC-4000Hg SKU: TEC-4000HG Description
The Apex TEC-4000Hg Thermoelectric Gas Cooler is a 19-inch rack-mounted gas cooler designed to be used in conjunction with the STM-6000RM Automated Mercury Sampling Console. The sample gas is cooled for the purpose of condensing the water vapor and water-soluble acids prior to measurement with the metering console. The condensate is collected in plastic-coated reagent bottles connected to the bottom of the condensers. The condensate freely drains into the bottles without the need of a pump. Dry acid-free sample gas is crucial for protecting the sample pumps and measurement devices. The bottles are sized for collecting up to one week of condensate from a source with 20% moisture when sampling at 500 ccm. The condensate can be measured for determining the approximate percent water vapor in accordance with EPA Method 4. Gases are drawn through a dry sorbet scrubber for removing residual water vapor and corrosive gases. For maximum performance, the thermoelectric module is coupled with a highly efficient heat exchanger for removing the heat from the hot side of the module to the ambient air. The heat exchanger includes a copper base fitted with six U-tube heat pipes with coated fins and a high-volume corrosion-resistant fan.
Features
Extremely reliable solid-state heat pump with a long lifespan
Pinnacle solid-state heat pump is housed in a rugged package that is easy to service and designed to withstand harsh industrial environments
Low-resistance heat exchanger with a copper base and heat pipes with high thermal conductivity
Heat pump unit includes an aluminum block fitted with two Hastelloy condensers, a thermoelectric module, a high-efficiency heat exchanger, an exhaust fan, and a PID temperature controller
Thermoelectric module is coupled with a highly efficient heat exchanger for removing the heat from the hot side of the module to the ambient air
Low-resistance, high-efficiency heat exchanger includes a copper base fitted with six U-tube heat pipes with coated fins and a high-volume, corrosion-resistant fan
Specifications
Refrigeration: Thermoelectric heat pump: 59-watt solid-state module
Temperature display: OLED display +/- 0.1 ºC/ºF
Temperature control: Variable direct current with PID control, 3-button keypad
Cooling capacity: 100 BTU/hr
Cold block: Insulated aluminum
Condenser: Reverse flow condensate separator, C276 alloy, 1×7 inch dimensions, 4-inch active cooling zone
Condensate removal: Gravity bottle, 10 mL/min
Heat exchanger: Low-profile heatsink with six 6-mm diameter U-tube heat-pipes, coated fins for corrosion resistance, 120-mm axial fan, with encapsulated motor and electronics
Rated flow rate: 2 LPM at 30% moisture per channel
Ambient operating temperature: 32 to 104 ºF. (0 to 40 ºC)
Auxiliary temperature controller: Digital temperature controller for heated jumper, type-K thermocouple input
Power: Supply 120V AC at 60 Hz 15 amps max., or 240VAC at 50 Hz 10 amps max., IEC C-13 inlet
Dimensions: 17 x 7 x 17 inches (43.2 cm x 27.8 cm x 43.2 cm)
Weight: 22 lbs (10 kg)
Code: SKU: TEC-4000HG
Description
The Apex TEC-4000Hg Thermoelectric Gas Cooler is a 19-inch rack-mounted gas cooler designed to be used in conjunctio...
TEC-4000HgP TEC-4000HgP SKU: TEC-4000HGP Description
Portable Mercury Gas Cooler for Method 30B
The sample gas is cooled for the purpose of condensing the water vapor and water-soluble acids prior to measurement with the metering console. The condensate is collected in plastic-coated reagent bottles connected to the bottom of the condensers. The condensate freely drains into the bottles without the need of a pump. Dry, acid-free sample gas is crucial for protecting the sample pumps and measurement devices. The bottles are sized for collecting up to one week of condensate from a source with 20% moisture when sampling at 500 cubic centimeters per minute. The condensate can be measured for determining the approximate percent water vapor in accordance with EPA Method 4. Gases are drawn through a dry sorbet scrubber for removing residual water vapor and corrosive gases.
Features
Extremely reliable solid-state heat pump with a long lifespan
Pinnacle solid-state heat pump is housed in a rugged package that is easy to service and designed to withstand harsh industrial environments
Low-resistance heat exchanger with a copper base and heat pipes with high thermal conductivity
Heat pump unit includes an aluminum block fitted with two Hastelloy condensers, a thermoelectric module, a high-efficiency heat exchanger, an exhaust fan, and a PID temperature controller
Thermoelectric module is coupled with a highly efficient heat exchanger for removing the heat from the hot side of the module to the ambient air
Low-resistance, high-efficiency heat exchanger includes a copper base fitted with six U-tube heat pipes with coated fins and a high-volume, corrosion-resistant fan
Specifications:
Refrigeration: Thermoelectric heat pump: 59-watt solid-state module
Temperature display: OLED display +/- 0.1 ºC/ºF
Temperature control: Variable direct current with PID control, 3-button keypad
Cooling capacity: 100 BTU/hr
Cold block: Insulated aluminum
Condenser: Reverse flow condensate separator, C276 alloy, 1”x7” dimensions, 4” active cooling zone
Condensate removal: Gravity bottle, 10 ml/min
Heat exchanger: Low-profile heatsink with six 6-mm diameter U-tube heat-pipes, coated fins for corrosion resistance, 120-mm axial fan, with encapsulated motor and electronics
Rated flow rate: 2 lpm at 30% moisture per channel
Ambient operating temperature: 32 to 104 ºF. (0 to 40 ºC)
Power: Supply 120V AC/60 Hz 15 amps max. or 240VAC 50 Hz 10 amps max., IEC C-13 inlet
Dimensions: 17”x7”x17” (43.2 cm x 27.8 cm x 43.2 cm)
Weight: 22 lbs. (10 kg)
Code: SKU: TEC-4000HGP
Description
Portable Mercury Gas Cooler for Method 30B
The sample gas is cooled for the purpose of condensing the water vapor and water...
TEC-4000HgP-V TEC-4000HgP-V SKU: TEC-4000HGP-V Description
The Apex TEC-4000Hg Thermoelectric Gas Cooler is a 19-inch rack-mounted gas cooler designed to be used in conjunction with the STM-6000RM Automated Mercury Sampling Console. The sample gas is cooled for the purpose of condensing the water vapor and water-soluble acids prior to measurement with the metering console. The condensate is collected in plastic-coated reagent bottles connected to the bottom of the condensers. The condensate freely drains into the bottles without the need of a pump. Dry acid-free sample gas is crucial for protecting the sample pumps and measurement devices. The bottles are sized for collecting up to one week of condensate from a source with 20% moisture when sampling at 500 ccm. The condensate can be measured for determining the approximate percent water vapor in accordance with EPA Method 4. Gases are drawn through a dry sorbet scrubber for removing residual water vapor and corrosive gases. For maximum performance, the thermoelectric module is coupled with a highly efficient heat exchanger for removing the heat from the hot side of the module to the ambient air. The heat exchanger includes a copper base fitted with six U-tube heat pipes with coated fins and a high-volume corrosion-resistant fan.
Features
Extremely reliable solid-state heat pump with a long lifespan
Pinnacle solid-state heat pump is housed in a rugged package that is easy to service and designed to withstand harsh industrial environments
Low-resistance heat exchanger with a copper base and heat pipes with high thermal conductivity
Heat pump unit includes an aluminum block fitted with two Hastelloy condensers, a thermoelectric module, a high-efficiency heat exchanger, an exhaust fan, and a PID temperature controller
Thermoelectric module is coupled with a highly efficient heat exchanger for removing the heat from the hot side of the module to the ambient air
Low-resistance, high-efficiency heat exchanger includes a copper base fitted with six U-tube heat pipes with coated fins and a high-volume, corrosion-resistant fan
Specifications
Refrigeration: Thermoelectric heat pump: 59-watt solid-state module
Temperature display: OLED display +/- 0.1 ºC/ºF
Temperature control: Variable direct current with PID control, 3-button keypad
Cooling capacity: 100 BTU/hr
Cold block: Insulated aluminum
Condenser: Reverse flow condensate separator, C276 alloy, 1×7 inch dimensions, 4-inch active cooling zone
Condensate removal: Gravity bottle, 10 mL/min
Heat exchanger: Low-profile heatsink with six 6-mm diameter U-tube heat-pipes, coated fins for corrosion resistance, 120-mm axial fan, with encapsulated motor and electronics
Rated flow rate: 2 LPM at 30% moisture per channel
Ambient operating temperature: 32 to 104 ºF. (0 to 40 ºC)
Auxiliary temperature controller: Digital temperature controller for heated jumper, type-K thermocouple input
Power: Supply 120V AC at 60 Hz 15 amps max., or 240VAC at 50 Hz 10 amps max., IEC C-13 inlet
Dimensions: 17 x 7 x 17 inches (43.2 cm x 27.8 cm x 43.2 cm)
Weight: 22 lbs (10 kg)
Code: SKU: TEC-4000HGP-V
Description
The Apex TEC-4000Hg Thermoelectric Gas Cooler is a 19-inch rack-mounted gas cooler designed to be used in conjunctio...
TEC-CS4000 TEC-CS4000 SKU: TEC-CS4000
TEP-1612 Portable Peltier Single-Stage Gas Cooler TEP-1612 Portable Peltier Single-Stage Gas Cooler SKU: TEP-1612 Description
The TEP-1612 Portable Peltier Single-Stage Gas Cooler removes water vapor from process gas samples prior to gas analysis. The TEP-1612 has an aluminum block containing a single-pass stainless-steel condenser, a peristaltic pump for condensate removal, and three auxiliary temperature controllers (probe, oven and heated sample line jumper). The rugged and lightweight design allows the cooler to be used on the sampling platform, close to the source.
Features
Portable, compact, and lightweight
Rugged 24v solid-state thermoelectric heat pumps
OLED display with power monitor
IP-rated switching power supply
Variable DC voltage PID controller for thermoelectric module
Integrated peristaltic pump for condensate removal
Easily removable condenser
Insulated aluminum cold block
Dual high-output axial fans are coupled with thermosiphon heat exchangers to support the thermoelectric units and allow the gas conditioner to operate in a wider range of ambient conditions
Specifications
Pinnacle Heat Pump System: Two 80-watt solid-state modules
Temperature Display: OLED display +/- 0.1 °C/°F
Temperature Control: Variable DC voltage controller, 3-button keypad
Cold Block: Insulated aluminum
Condenser: Alloy 316 stainless steel, reverse flow condensate separator, various coatings available, 1” OD x 12”
Condensate Removal: Integrated peristaltic pump, 10 ml/min
Radiator: Two high flow, low-profile heat sinks 120-mm axial fans, with encapsulated motor and electronics
Rated Moisture Extraction Capacity: 14% moisture at 10 lpm (75° ambient) with a less than 1% target moisture rate.
Auxiliary Temperature Controllers: Digital temperature controllers for probe, oven, and heated jumper; type-K thermocouple input
Ambient Operating Temperature: 32 to 104 °F (0 to 40 °C) Standard Flow Rate: 1 to 15 lpm, single channel Tubing Size: 1/4“ diameter standard or 3/8” fittings provided
Accessories: Companion condenser, peristaltic pump (optional), separate strain reliefs
Dimensions: 10.25” W x 16.5” H x 9.25” D (260 mm W x 419 mm H x 235 mm D) Weight: 30.7 lbs (13.9 kg)
Code: SKU: TEP-1612
Description
The TEP-1612 Portable Peltier Single-Stage Gas Cooler removes water vapor from process gas samples prior to gas anal...
Tubular Zone Heater Tubular Zone Heater SKU: Tubular Zone Heater
Code: SKU: Tubular Zone Heater
VSB2 VSB2 SKU: VSB2 Description
Dimensions: H x W x D – 24 x 12 x 11 inches (61 x 30.5 x 27.9 cm)
The VSB2 VersaCase with hinged, removable doors. Includes PC-3/4E probe clamp.
Inside Cabinet Dimensions: H x W x D – 11.8 x 11.2 x 8.9 inches (30 x 28.5 x 22.5 cm)
Code: SKU: VSB2
Description
Dimensions: H x W x D – 24 x 12 x 11 inches (61 x 30.5 x 27.9 cm)
The VSB2 VersaCase with hinged, removable d...
VSB5 VSB5 SKU: VSB5 Description
The VSB-5 VersaCase is a lightweight portable lab frame ideal for supporting complex glassware setups. Originally designed to complement Model 623 sampling consoles for Volatile Organic Sampling (VOST). The unit features a pre-punched panel with a combination handle/monorail bracket, coolant reservoir brackets (accommodates standard modular impinger cases), and removable front and rear doors. Interchangeable probe clamps for 3/4-inch and 1-inch sheaths are available. Call for details on customized kits for other testing methods.
Dimensions: H x W x D – 11.8 inches x 11.2 inches x 8.9 inches (30 cm x 28.6 cm x 22.5 cm)
Code: SKU: VSB5
Description
The VSB-5 VersaCase is a lightweight portable lab frame ideal for supporting complex glassware setups. Originally designed to complemen...
VSB5-SCW Gas Condenser VSB5-SCW Gas Condenser SKU: VSB5-SCW Description
Versatile gas condenser
Features:
Lightweight
Dual-channel peristaltic pump
Cam-lock for secure, leak-free connection
Code: SKU: VSB5-SCW
Description
Versatile gas condenser
Features:
Lightweight
Dual-channel peristaltic pump
Cam-lock for secure...
XC-11 Console XC-11 Console SKU: XC-11 Console Description
Sample gas enters the console via a 1/4-inch stainless steel quick connect sample inlet. Sample gas flow is easily controlled by means of a panel-mounted needle valve with a round phenolic control knob and is displayed through an acrylic plastic rotameter mounted to the front panel. Two dial thermometers, one mounted to the meter inlet and one mounted to the meter outlet, measure the sample gas temperature entering and exiting the meter.
Features
1/4-inch stainless steel quick-connect sample inlet
Sample gas flow is easily controlled by means of a panel-mounted needle valve with a round phenolic control knob
All components are packaged neatly into a compact, durable, light weight transport case
Acrylic plastic rotameter mounted to the front panel
Two dial thermometers, one mounted to the meter inlet and one mounted to the meter outlet www.apexinst.com
The system is similar to a Method 6 console with the exception of having no internal pump
An external pump is used to purge the train after sampling
5-point low flow calibration • Precision dry gas meter securely mounted to the front panel
Specifications
Dry gas meter: DGM-SK25EX., 0.7 liters per rotation
DGM calibration: range: 0.05 to 2.5 LPM, 5-point low flow calibration, part number: DGMC-5A-LFB
Inlet quick connect: 1/4-inch female quick connect, stainless steel
DGM thermometers: dial-type inlet: 20°F to 130ºF, exhaust: 20°F to 130°F
Rotameter: 0 to 2.5 LPM
Flow control: panel-mounted needle valve
Outlet: 1/4-inch stainless steel tube stub
Transport case: 14.5” H x 11.5” W x 7.25” D (37 cm x 29 cm x 18.5 cm)
Weight: 12 lbs (5.4 kg)
Code: SKU: XC-11 Console
Description
Sample gas enters the console via a 1/4-inch stainless steel quick connect sample inlet. Sample gas flow is easily controlled by mean...
XC-260 Console XC-260 Console SKU: XC-260 Console Description
The XC-260 Manual Mercury Source Sampler is designed for performance testing, baseline studies, and profiling. This low-cost, easy-to-use, portable, and field-proven audit system is ideal for sampling mercury emissions based on Reference Method 30B of the U.S. EPA Appendix K, 40 CFR, Part 60.
The XC-260 Mercury Audit System is used for manual sampling of gaseous mercury emissions over a period of several minutes to several hours. The system extracts two separate flue gas samples through co-located sorbent traps attached to the end of a heated sample probe.
Mercury is collected in the sorbent traps for a predetermined sampling period. The traps are easily transported for analysis. The average mercury concentration for the sampling period is determined by using the sample volumes measured by the dry gas meters and the results of the sorbent trap analysis. Sample data is manually recorded at the beginning and end of each sample collection period as well as periodically during the collection period. All temperature, pressure, and flow measurement data are conveniently displayed and can be easily entered into a spreadsheet for analysis.
The XC-260 source sampler is also ideal for sorbent tube sampling for Method 18, the measurement of gaseous organic compound emissions by gas chromatography.
Features:
Dual independent flow paths
Dual dry gas meters with digital displays
Coarse and fine valves for precise flow and vacuum control
Stainless steel valves and fittings
Stainless steel 1/4-inch quick connects
Digital temperature controller for probe heater
Elapsed digital timers
Dual-scale vacuum gauge
Rugged and lightweight roto-molded linear low-density polyethylene (LLDPE/LMDE) case with two molded-in ergonomic carrying handles (size 10U)
Specifications:
Dry gas meters:
Model SK25EX series
Positive displacement diaphragm type
0.7 liters per revolution
Optical encoder sensor
Quadrature pulse output
Gas volume totalizer with an eight-digit LCD display
1 cubic cm resolution (standard)
Dual-diaphragm sample pumps: (2) 12 VDC motors, max vacuum 20 inHg
Probe temperature control:
Compact, 1/32 DIN auto-tuning indicating temperature controller with external 25-amp solid-state relay
115 VAC outlet 5-15R, standard type-K jack for input
Digital temperature display: 3.5-digit display °F (-157°F to 1999°F), display and controller are resettable for °C upon request (°C is standard for export)
Thermocouple inputs: Five external type-K inputs plus two type-K internal gas meter connections
Flowmeters:
Solid machined acrylic, stainless steel float
A: 0.1 – 1.0 LPM
B: 0.2 – 2.4 LPM
C: 0.2 – 4.0 LPM
AC Power: 120 V at 60 Hz or 240 V at 50 Hz optional
Dimensions: 23” x 21” x 12” (58 cm x 53 cm x 30.5 cm)
Weight: 39 lbs (17.7 kg)
Code: SKU: XC-260 Console
Description
The XC-260 Manual Mercury Source Sampler is designed for performance testing, baseline studies, an...
XC-3D55 Console XC-3D55 Console SKU: XC-3D55 Description
The XC-3D55 Flow Measurement Console is used in conjunction with various pitots to determine velocity pressure, and the yaw and pitch angles of the flow velocity vector in a stack or duct according to U.S. EPA Method 2, 2F or 2G (the determination of stack gas velocity and volumetric flow rate with three-dimensional probes). The XC-3D55 console easily interfaces with the UINC-3D-__ Umbilical/Inclinometer Assembly through a series of 1/4-inch quick connects, a 4-pin circular connector and a type-K thermocouple jack. Readings for stack temperature, velocity pressure, pitch pressure, and yaw angle are displayed respectively through a display, process meters and a totalizer. The null angle is displayed through a magnehelic.
Features
Digital display totalizer
Magnehelic gauge
Rocker switch
1/4-inch quick connects
Amphenol
Type-K thermocouple jack
IEC plug/receptacle
Blow-back pump
Power supply transducers modular/plastic enclosure
Probe sensor inclinometer and digital indicator
Rugged and reliable construction for any environment
Code: SKU: XC-3D55
Description
The XC-3D55 Flow Measurement Console is used in conjunction with various pitots to determine velocity pressure, and the yaw and pitch...
XC-5000 Console XC-5000 Console SKU: XC-5000 Console Description
The XC-5000 Autokinetic™ Sampling Console is designed for conducting US EPA Method 5 and associated isokinetic methods. Take the worry out of isokinetic sampling and the human error out of manual data entries and calculations. The XC-5000 is compatible with your existing Method 5 stack sampling components. Report preparation is streamlined with accurate data that can be downloaded for easy report preparation. Bright LED screen displays port, point, time, vacuum and other information readable in most lighting conditions. The AutoKinetic proprietary software is designed to be intuitive and user-friendly. The stepwise functionality of the windows-based program guides the user through the creation of a complete test profile ensuring all test parameters are met and while assuring data integrity. The software also allows for quick and easy data export for report generation.
Features and benefits:
Fully automated isokinetic sampling console improves data integrity
Improves precision and provides quality measurements
Rugged and lightweight roto-molded linear low-density polyethylene (LLDPE/LMDE) case with two molded-in ergonomic carrying handles
Windows-based interface guides the operator through the sampling process
Calculates traverse points, ideal nozzle diameter, and isokinetic rate
Accepts standard modules for various EPA Methods
Software assisted pre- and post-leak checks
Optional automatic pause function
Notifies you to move the probe
Alarms for user attention
Stores sampling profiles and data
English or metric units
Multilingual language editor
Sunlight-readable LED display
Specifications:
Dry Gas Meter: precision DGM, 0.7 liters per revolution, digital encoder, 0.2 liters resolution
Temperature Control: integrated temperature control via the control and data acquisition board, probe, and even with solid-state relays
Thermocouple Display: seven temperatures displayed simultaneously on the PC user interface, °F or °C, probe, stack, oven, filter, exit, aux, and DGM
Digital Pressure Transducers: for ΔH, and ΔP (bi-directional), barometric
Pitot ΔP
Range: +/-2.5 inches, +/- 63 mm
Resolution: 0.01 inch, 0.1 mm
Orifice ΔH
Range: 0 – 5 inches, 0 – 127 mm
Resolution: 0.01 inch, 0.1 mm
Barometric
Range: 17.7 – 32.5 inHg, 450 – 825 mmHg
Resolution: 0.01 inHg, 0.1 mmHg
Vacuum sensor
Range: 0-30 inHg, 0-101 kPa
2% accuracy
Umbilical Connections:
Electrical: 4-conductor circular connector, grounded shell
Sample line: stainless steel 1/2-inch quick connect
Pitot line: stainless steel 1/4-inch quick connects (optional 3/8”)
External pump: stainless steel 3/8-inch quick connect
Thermocouples: type-K standard size
Communication: ethernet
Dimensions: H23” x W21” x D12” (58 cm x 53 cm x 30.5 cm)
Weight: 39 lbs (17.7 kg)
Power: 120 V at 60 Hz or 240 V at 50 Hz (optional)
Console Power Requirements: 15 amp max
Code: SKU: XC-5000 Console
Description
The XC-5000 Autokinetic™ Sampling Console is designed for conducting US EPA Method 5 and associated isokinetic met...
XC-523 Console XC-523 Console SKU: XC-523 Console Description
The XC-523 Imperial Sampling Console is a full-featured, compact, and lightweight Isokinetic Source Sampler. It has all the great features you want and the reliability you need. Field set up is easy with non-reversible external pump connections and the industry standard 5-pin electrical connector. The console allows operators to monitor gas velocities, temperatures, pressures, and sample flow rates for maintaining isokinetic sampling conditions. The XC-523 displays imperial units. For metrics, please view our XC-572 model.
Features:
Precision gas meter with orifice
Rugged, lightweight and stackable roto-molded case with two ergonomic handles and carrying strap for easy transport
Removable 19-inch front panel
Non-reversible sample pump connections
Color-coded thermocouple jacks
Bright, easy-to-read temperature displays
Easy-leveling dual-column manometer
Stainless steel quick connects and fittings
Specifications:
Dry gas meter, DIGI-SK25:
The new DIGI-SK25 is fitted with an optical encoder and an LED totalizer which receives incoming pulses and multiplies them by the scaling factor to obtain measured volume.
The DIGI-SK25’s features include:
A high-resolution optical encoder with 400 pulses per revolution
Bright, easy-to-read 8-digit LED totalizer
Quadrature sensing prevents false counts due to vibrations
Totalizes up to 999.9999 ft3
Accuracy less than 1.5%
Multi-chamber positive displacement meter (fitted with a quadrature encoder)
Qmax for air 68 lpm (2.4 ft3/min) at 220 Pa
Qmin 0.00007 ft3
Cyclic volume 0.025 ft3
400 pulses per revolution
Type-K thermocouple for exit temperature
Manometer:
Dual-inclined/vertical manometer for determining stack velocity and sample flow rate
Inclined range 0-1.0” H20 with 0.01 divisions, vertical range 1-10 in H2O with 0.1 divisions
Fabricated from solid acrylic, precision-bored, accurate to +/- 1%, convenient self-sealing chrome-plated brass quick-connects with Viton O-rings, supplied with plastic plugs for positive secondary seal
Temperature Display:
Panel mount digital thermometer
Bright red LED display
Range -157° to 1999°F, with separate 7-channel selector switch
Volume Display:
Panel mount
Bright red LED display totalizer
Resettable
Temperature Controllers For Probe And Oven:
Fuji PXR3 compact, 1/32 DIN self-tuning PID temperature controller with 3-button keypad
SSR driver for 25-amp solid state relay
Type-K thermocouple jack for input °C/°F selectable, -200°C to 1372°C range. (-328°F to 2502°F)
Vacuum Gauge:
Dual-scale vacuum gauge, 0-30 inHg / 0-100 kPa
Sample Pump Connections:
3/8-inch quick connects, stainless steel, non-reversible
Umbilical Connections:
Sample inlet: 1/2-inch stainless steel quick connect
Pitot lines: 1/4-inch (3/8-inch optional) stainless steel quick connect
Electrical: 4 conductor circular connector
Thermocouples: 6 type-K inputs, standard size
Electrical:
4 conductor circular connector
Thermocouples
6 type-K inputs, standard size
Power: 120 V at 60 Hz standard, or 240 V at 50 Hz optional
Dimensions: 23” x 21” x 12” (58 x 53 x 30cm) 19-inch panel
Weight: 43 lbs. (19.5 kg)
Code: SKU: XC-523 Console
Description
The XC-523 Imperial Sampling Console is a full-featured, compact, and lightweight Isokinetic Source Sampler. It has ...