Heated Filter Assembly Heated Filter Assembly SKU: Heated Filter Assembly
Code: SKU: Heated Filter Assembly
HGP-1SJ HGP-1SJ SKU: HGP-1SJ
HGP-SH-C-EXT6 HGP-SH-C-EXT6 SKU: HGP-SH-C-EXT6
HGP-SH-S-EXT6 HGP-SH-S-EXT6 SKU: HGP-SH-S-EXT6
HGU-6DJ HGU-6DJ SKU: HGU-6DJ Description
U-Cord Jumper, mercury, 6 foot, male quick connects included
Code: SKU: HGU-6DJ
Description
U-Cord Jumper, mercury, 6 foot, male quick connects included...
HGU-6DJ-6 HGU-6DJ-6 SKU: HGU-6DJ-6 Description
U-cord jumper, mercury, 6 foot
Code: SKU: HGU-6DJ-6
Description
U-cord jumper, mercury, 6 foot...
High/Low Range Continuous Moisture Analyzer Probe – High High/Low Range Continuous Moisture Analyzer Probe – High SKU: MAC155-H Description
High-range continuous moisture analyzer probe with internal 2-point calibrator, must be purchased with MAC155-CT, selectable ranges of 3% to 15%, 6% to 30%, 9% to 45%, or 12% to 60%
Code: SKU: MAC155-H
Description
High-range continuous moisture analyzer probe with internal 2-point calibrator, must be purchased with MAC155-CT, selectable ranges of ...
High/Low Range Continuous Moisture Analyzer Probe – Low High/Low Range Continuous Moisture Analyzer Probe – Low SKU: MAC155-L Description
Low-range continuous moisture analyzer probe with internal 2-point calibrator, must be purchased with MAC155-CT, selectable ranges of 3% to 15% or 6% to 30%
Code: SKU: MAC155-L
Description
Low-range continuous moisture analyzer probe with internal 2-point calibrator, must be purchased with MAC155-CT, selectable ranges of 3...
HVACR KIT HVACR KIT HVACR
ICE-16 ICE-16 SKU: ICE-16
Imperial Measurement Slide Rule Stack Calculator Imperial Measurement Slide Rule Stack Calculator SKU: M5A-1 Description
If sampling is located outside and isin inconvenient locations, a calculator is difficult if not impossible to use. In the haste of preparing to sample, mistakes are easily made using the equations. Also a ready reference is needed to correlate the pitot tube AP with the required orifice meter AH setting. A calculator is nconvenient for this purpose. As a result of these problems, a manual slide rule calculator was developed that is simple to operate and easily understood. It can be used to find both proper nozzle size and sampling rate. When the calculation of K factor is complete, the slide can be locked into place and the AP and AH scales are properly aligned for isokinetic sampling.
English and Metric measurement units available.
Code: SKU: M5A-1
Description
If sampling is located outside and isin inconvenient locations, a calculator is difficult if not impossible to use. In the haste of pre...
In-Stack Thimble Holder Kit In-Stack Thimble Holder Kit SKU: GFA-2590K Description
The GFA-2590K In-Stack Thimble Holder Kit includes a selection of the 7 most commonly used nozzle inserts form 1/8” to 1/2″ and one housing. The entire kit is conveniently packaged in a foam-lined carrying case for protection. The Thimble holder connects directly to the end of the probe with a 5/8” tube union. One Metal Taper Clip is included in the kit. The unique integral nozzle design reduces weight and breakage. The entire assembly is lightweight and uses no O-Rings which allows for testing at much higher temperatures. Quartz filter assemblies are available for testing in temperatures up to 1000°C.
We offer 2 different filter media (Glass and Quartz). The Thimbles are seamless, high purity filters, tapered for ease in loading. The gas collection efficiency of the thimbles is 99.9% (%0.3 mm DOP). The Thimble Filter Media comes in boxes of 10.
GF-2590 – Glass fiber thimble, 25 x 90mm, max 500°C. These Borosilicate Glass Fiber Thimbles are acid washed to reduce the trace metal content to an absolute minimum.
GF-2590Q – Quartz fiber thimble, 25 x 90mm, max 1000°C. Silica Fiber Thimbles are strengthened with alumina and are prefired at 900°C for 2 hours during manufacturing to stabilize the weight prior to use.
**The conditional method for Ammonia (CTM-027) requires an In-Stack Method 17 Filter Holder constructed from Borosilicate glass or PFA and a glass fiber filter. The Apex GFA-2590 Thimble holder is constructed totally from Borosilicate Glass and accepts tapered 25 x 90 mm thimbles especially manufactured for stack sampling. Our design does not require the use of o-rings. This allows for testing at higher temperatures. The borosilicate glass will withstand temperatures up to 900°F (480°C).
Code: SKU: GFA-2590K
Description
The GFA-2590K In-Stack Thimble Holder Kit includes a selection of the 7 most commonly used nozzle inserts form 1/8” ...
INC-A300 Pendulum Style Inclinometer INC-A300 Pendulum Style Inclinometer SKU: INC-A300
Instrumental Quick Connects Instrumental Quick Connects SKU: Instrumental Quick Connects
Code: SKU: Instrumental Quick Connects
Insulated Blanket for SFA-82H Insulated Blanket for SFA-82H SKU: SFA-82-BKT Description
SFA-82-BKT Insulated blanket for SFA-82H and SFA-82H-V
Code: SKU: SFA-82-BKT
Description
SFA-82-BKT Insulated blanket for SFA-82H and SFA-82H-V
...
Integrated In-Stack Filter Assembly Kit Integrated In-Stack Filter Assembly Kit SKU: SGFA-47NK Description
The SGFA-47NK In-Stack Filter assembly kit features the unique design combination of borosilicate glass 47mm filter inlet with integrated nozzle, allowing the option to weigh the glass fiber filter media individually for Method 17 or very similar to Method 5I by weighing the combined nozzle & filter media with a support, O-Ring and PTFE Tape. The kit includes the standard array of seven nozzle sizes from 1/8 to 1/2.
Code: SKU: SGFA-47NK
Description
The SGFA-47NK In-Stack Filter assembly kit features the unique design combination of borosilicate glass 47mm filter inlet with integrat...
Isokinetic Air Cooled Probe Isokinetic Air Cooled Probe SKU: Air Cooled Probe Description
Our updated Method 5 Air-Cooled Probe design features a more robust alloy construction. Upgraded to 253MA with a new variable-speed high-capacity blower inside the riser, the new design will extend the life of the probe and increase the airflow by an additional 30%.
**Order blower separately. Order probe heater separately, if necessary.
Features
Welded nut and small parts (PK-ISP)
Modular alloy 600 pitots and reducing union
Variable-speed high-capacity blower
Specifications
Outer sheath: 253MA
Middle sheath: stainless steel
Inner sheath: 253MA
Liner, pitot tubes, thermocouple, nozzle union, and Orsat: alloy 600
Welded nut and small parts (PK-ISP)
*Method 5 Air-Cooled Probes now come standard with modular alloy 600 pitots and reducing union.
Code: SKU: Air Cooled Probe
Description
Our updated Method 5 Air-Cooled Probe design features a more robust alloy construction. Upgraded to 2...
JCP-300 JCP-300 Applications
Mobile extractive gas analysis
Emission and process monitoring
Continuous sample gas conditioning of humid process gases
Continuous drying of sample gas to a precise, low and constant outlet dew point
Minimises water vapour cross-sensitivities and volumetric errors
Applications
Mobile extractive gas analysis
Emission and process monitoring
Continuous sample gas conditioning of humid process gases
Continuous drying of the sample gas to a precise, low and constant outlet dew point
Minimises water vapour cross-sensitivities and volumetric errors
Benefits
Very powerful compact complete unit with condensate removal
High flow rates of up to 250 Nl/hr
Very low wash-out ratios, even at high water vapour concentrations in the sample gas
High inlet dew points up to 80 °C are possible
Reliable condensate separation even at very high ambient temperatures up to 50 °C
Extremely precise, long-term stable dew point even under varying loads
Maximum operational safety
Low maintenance operation
Easy to maintain design
Features
New, powerful, modular designed compact solution
New heat exchanger JHEX-4
Intelligent digital control electronic
Digital temperature display
Up to an ambient temperature of 50 °C (JCP-310) applicable
Integrated condensate pump
Integrated sample gas pump
Integrated flow control
Integrated fine dust filter
Integrated condensate monitoring
Temperature controller for heated sample line
Visual alerting via LEDs and digital display
Self-monitoring with deactivation of the sample pump in case of alarm
Ready for operation within less than 15 minutes
Code: JCP-300
Applications
Mobile extractive gas analysis
Emission and process monitoring
Continuous sample gas conditioning of humid process gases
Continuous drying of sample gas to a precise, low and constant outlet dew point
Minimises water vapour cross-sensitivities and volumetric errors
JH3FG & JH3FGR JH3FG & JH3FGR Applications
For extractive gas analysis
For emission and process monitoring
For the transport of sample gas from the sample point to the analysis system
To stay safely above the acid dew point
For protection against measured value falsification and frost
For indoor and outdoor use
Applicable for portable systems
Applications
For extractive gas analysis
For emission and process monitoring
For the transport of sample gas from the sample point to the analysis system
To stay safely above the acid dew point
For protection against measured value falsification and frost
For indoor and outdoor use
Applicable for portable systems
Benefits
No condensate formation, no freezing
Close bending radius possible
Excellent thermal insulation
Optimal heat deployment
Customized configurations
Easy exchange of the inner core (JH3FGR)
Long lifetime also in portable applications
Kink protection
Features
Regulated heatable to max. 200 °C
External jacket flexible protection braid of polyamide
Heat insulation with silicone foam
Ready for use
Very flexible
Interchangeable inner core for JH3FGR
Second core for e.g. calibration gas as an option
Integrated temperature controller as an option
Inner core reinforced with stainless steel braid
Code: JH3FG & JH3FGR
Applications
For extractive gas analysis
For emission and process monitoring
For the transport of sample gas from the sample point to the analysis system
To stay safely above the acid dew point
For protection against measured value falsification and frost
For indoor and outdoor use
Applicable for portable systems
JPES JPES Portable Gas Sampling Probe with JHSo Heated Sample Line
Applications
For mobile extractive gas analysis
For emission and process monitoring
For mobile representative gas sampling in dust and humidity containing processes
For removal of dust from the sample gas stream
For condensate free transport from the sampling point to the conditioning system or the analyser
Especially designed for:
stack testers
authorities (QAL 2)
mobile back-up CEMS Portable Gas Sampling Probe with JHSo Heated Sample Line
Applications
For mobile extractive gas analysis
For emission and process monitoring
For mobile representative gas sampling in dust and humidity-containing processes
For the removal of dust from the sample gas stream
For condensate-free transport from the sampling point to the conditioning system or the analyser
Especially designed for:
stack testers
authorities (QAL 2)
mobile back-up CEMS
Benefits
Lightweight and compact
Quick and very easy start-up
Very easy operation
Very easy and quick change of the filter element without tools
Complete, ready for use set, no additional equipment necessary
No separate temperature controller necessary
Only one power connection is necessary (also with the heated sampling tube JBER)
No loose cables
Features
Robust, compact transport case with all necessary parts for mobile gas sampling: gas sampling probe, heated sample line, sampling tubes, filter elements, calibration gas connection, mounting chains, …
Compact gas sampling probe with operation and temperature status LEDs
Homogeneous heating to 180 °C without cold spots
Gas sampling probe with self-limiting PTC heating element
Calibration gas connection at the gas sampling probe
Heated sample line JHSo with integrated temperature controller and operation status LED
All electric connection cables are integrated in the heated sample line
Exclusively Quick-On connectors for all gas connections
Flexible, light weight and robust heated sample line
Comprehensive list of options for various applications
Code: JPES
Portable Gas Sampling Probe with JHSo Heated Sample Line
Applications
For mobile extractive gas analysis
For emission and process monitoring
For mobile representative gas sampling in dust and humidity containing processes
For removal of dust from the sample gas stream
For condensate free transport from the sampling point to the conditioning system or the analyser
Especially designed for:
stack testers
authorities (QAL 2)
mobile back-up CEMS
KANE-GCU Gas Conditioning Unit KANE-GCU Gas Conditioning Unit KANE
KANE-HUB2 KIT Monobloc Heat Pumps KANE-HUB2 KIT Monobloc Heat Pumps KANE-HUB2
KANE-HUB4 KIT Heat Pumps & A/C KANE-HUB4 KIT Heat Pumps & A/C KANE-HUB4
KANE-HUB6 KIT System Evac, Superheat & Subcool KANE-HUB6 KIT System Evac, Superheat & Subcool KANE-HUB6